{"title":"Thermostatic Mixing Valves","description":"","products":[{"product_id":"thermomix-thermostatic-mixing-valve","title":"Thermomix Thermostatic Mixing Valve","description":"\u003cp\u003e\u003cb\u003eDESCRIPTION:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves (TMVs) blend hot and cold water. They employ a temperature sensitive element which expands and contracts depending on the temperature of the water entering the valve. This expansion and contraction alters the size of the apertures through which the hot and cold water enters the valve, thereby balancing and controlling the temperature of the water leaving the outlet, e.g. the tap, and so greatly reduces the risk of scalding accidents.\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves should ideally be used in all cases where there is a risk of scalding to the user; notably the very young, the very old and those requiring special needs. They are also vital components in (to name but a few): underfloor heating systems, solar powered domestic hot water systems, process control and legionella control. They are fitted to the hot inlet pipe directly before the terminal fitting. They require a hot and cold water supply to work.\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves should be fitted at each outlet and no further than 2 meters from the terminal. The length limit is part of current guidance in the UK on the prevention and control of legionella. In addition, the length of any spur to a TMV, from a hot water circulation system should not exceed 5 meters. It can be seen that the length of any pipework run containing water below 55˚C should be kept to a minimum. One minute is a long time to wait and most people would expect to wait perhaps only one third of this time. In order to understand what one minute means in terms of pipe length, this table provides an accurate insight.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/files\/TMIX123-1.jpg?v=1759569102\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Factory Temperature Setting: 38º C\u003c\/p\u003e\n\u003cp\u003e- Temperature Setting Range: 35º - 46º C\u003c\/p\u003e\n\u003cp\u003e- Temperature (Hot Supply): 52º - 65º C\u003c\/p\u003e\n\u003cp\u003e- Temperature (Cold Supply): 5º - 20º C\u003c\/p\u003e\n\u003cp\u003e- Minimum Hot To Mix Differential Temp: 10º C\u003c\/p\u003e\n\u003cp\u003e- Temperature Stability: ± 2º C\u003c\/p\u003e\n\u003cp\u003e- Working Pressure, Static: 10 Bar Max\u003c\/p\u003e\n\u003cp\u003e- Working Pressure, Dynamic: Low (0.2–1 Bar), High (1.0–5 Bar)\u003c\/p\u003e\n\u003cp\u003e- Flow Rate Minimum: 4L\/min\u003c\/p\u003e\n\u003cp\u003e- Flow Rate @ 1 Bar Pressure Loss: 21L\/min.\u003c\/p\u003e","brand":"Excel Industries","offers":[{"title":"1\/2\"","offer_id":51553680195912,"sku":"TMIX123","price":51.5,"currency_code":"EUR","in_stock":true},{"title":"3\/4\"","offer_id":51553716175176,"sku":"TMIX343","price":59.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/files\/TMIX123.jpg?v=1759569491"},{"product_id":"carlo-poletti-commercial-thermostatic-mixing-valves","title":"Carlo Poletti Commercial Thermostatic Mixing Valves","description":"\u003cp\u003e\u003cb\u003eDESCRIPTION:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves (TMVs) blend hot and cold water. They employ a temperature sensitive element which expands and contracts depending on the temperature of the water entering the valve. This expansion and contraction alters the size of the apertures through which the hot and cold water enters the valve, thereby balancing and controlling the temperature of the water leaving the outlet, e.g. the tap, and so greatly reduces the risk of scalding accidents.\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves should ideally be used in all cases where there is a risk of scalding to the user; notably the very young, the very old and those requiring special needs. They are also vital components in (to name but a few): underfloor heating systems, solar powered domestic hot water systems, process control and legionella control. They are fitted to the hot inlet pipe directly before the terminal fitting. They require a hot and cold water supply to work.\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves should be fitted at each outlet and no further than 2 meters from the terminal. The length limit is part of current guidance in the UK on the prevention and control of legionella. In addition, the length of any spur to a TMV, from a hot water circulation system should not exceed 5 meters. It can be seen that the length of any pipework run containing water below 55˚C should be kept to a minimum. One minute is a long time to wait and most people would expect to wait perhaps only one third of this time. In order to understand what one minute means in terms of pipe length, this table provides an accurate insight.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/files\/T20012-1.jpg?v=1759569654\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- For Use with Clean Water: 30°C - 65°C\u003c\/p\u003e\n\u003cp\u003e- Maximum Working Temp.: 85°C\u003c\/p\u003e\n\u003cp\u003e- Maximum Static Pressure: 10 bar\u003c\/p\u003e\n\u003cp\u003e- Maximum Dynamic Pressure: 5 bar\u003c\/p\u003e\n\u003cp\u003e- Maximum Pressure Differential: 2:1\u003c\/p\u003e\n\u003cp\u003e- Temperature Tolerance: ± 2°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Flow Rates to ensure normal functioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Models T20012 and T20034: 9L\/min\u003c\/p\u003e\n\u003cp\u003e- Models T20100 and T20114: 15L\/min\u003c\/p\u003e\n\u003cp\u003e- Models T20112 and T20200: 40L\/min.\u003c\/p\u003e","brand":"Excel Industries","offers":[{"title":"1\/2\"","offer_id":51553721680200,"sku":"T20012","price":153.36,"currency_code":"EUR","in_stock":true},{"title":"3\/4\"","offer_id":51553721712968,"sku":"T20034","price":165.1,"currency_code":"EUR","in_stock":true},{"title":"1\"","offer_id":51553738031432,"sku":"T20100","price":504.28,"currency_code":"EUR","in_stock":true},{"title":"1 1\/4\"","offer_id":51553738064200,"sku":"T20114","price":621.82,"currency_code":"EUR","in_stock":true},{"title":"1 1\/2\"","offer_id":51553738096968,"sku":"T20112","price":1779.8,"currency_code":"EUR","in_stock":true},{"title":"2\"","offer_id":51553738129736,"sku":"T20200","price":1967.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/files\/T20012.jpg?v=1759569918"},{"product_id":"thermomix-1-thermostatic-mixing-valve","title":"Thermomix 1\" Thermostatic Mixing Valve","description":"\u003cp\u003e\u003cb\u003eDESCRIPTION:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves (TMVs) blend hot and cold water. They employ a temperature sensitive element which expands and contracts depending on the temperature of the water entering the valve. This expansion and contraction alters the size of the apertures through which the hot and cold water enters the valve, thereby balancing and controlling the temperature of the water leaving the outlet, e.g. the tap, and so greatly reduces the risk of scalding accidents.\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves should ideally be used in all cases where there is a risk of scalding to the user; notably the very young, the very old and those requiring special needs. They are also vital components in (to name but a few): underfloor heating systems, solar powered domestic hot water systems, process control and legionella control. They are fitted to the hot inlet pipe directly before the terminal fitting. They require a hot and cold water supply to work.\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Valves should be fitted at each outlet and no further than 2 meters from the terminal. The length limit is part of current guidance in the UK on the prevention and control of legionella. In addition, the length of any spur to a TMV, from a hot water circulation system should not exceed 5 meters. It can be seen that the length of any pipework run containing water below 55˚C should be kept to a minimum. One minute is a long time to wait and most people would expect to wait perhaps only one third of this time. In order to understand what one minute means in terms of pipe length, this table provides an accurate insight.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/files\/HPT12-1.jpg?v=1759570937\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Factory Temperature Setting: 43º C\u003c\/p\u003e\n\u003cp\u003e- Temperature Setting Range: 35º - 46º C\u003c\/p\u003e\n\u003cp\u003e- Temperature (Hot Supply): 55º - 65º C\u003c\/p\u003e\n\u003cp\u003e- Temperature (Cold Supply): 5º - 25º C\u003c\/p\u003e\n\u003cp\u003e- Minimum Hot To Mix Differential Temp: 10º C\u003c\/p\u003e\n\u003cp\u003e- Temperature Stability: ± 2º C\u003c\/p\u003e\n\u003cp\u003e- Working Pressure, Static: 16 Bar Max\u003c\/p\u003e\n\u003cp\u003e- Working Pressure, Dynamic: Low (0.1–1 Bar), High (0.5–5 Bar)\u003c\/p\u003e\n\u003cp\u003e- Flow Rate Minimum: 4L\/min\u003c\/p\u003e\n\u003cp\u003e- Flow Rate @ 1 Bar Pressure Loss: 21L\/min.\u003c\/p\u003e","brand":"Excel Industries","offers":[{"title":"1\"","offer_id":51553783513416,"sku":"HPT12","price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/files\/HPT12_93b774fc-b917-4a37-85f6-d67b8f6fc514.jpg?v=1759571053"},{"product_id":"thermomix-tmixt-thermostatic-tap","title":"Thermomix TMIXT Thermostatic Tap","description":"\u003cp\u003e\u003cb\u003eDESCRIPTION:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Taps blend hot and cold water and deliver it at a safe and comfortable pre-calibrated and non user adjustable temperature of 41 Deg. Celsius. They employ a temperature sensitive element which expands and contracts depending on the temperature of the water entering the mixer tap. This expansion and contraction alters the size of the apertures through which the hot and cold water enters the tap; thereby balancing and controlling the outlet temperature of the water and in doing so reducing the risk of scalding accidents.\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Taps should ideally be used in all cases where there is a risk of scalding to the user; notably the very young, the very old and those requiring special needs.\u003c\/p\u003e\n\u003cp\u003eThey are therefore ideally suited for School, Hospital and Nursing Home and Health Care Premises application, where, in order to prevent the incidence of Legionella, the stored hot water will be at 60 Degrees Celsius or above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This tap delivers premixed hot water only!\u003c\/strong\u003e\u003c\/p\u003e","brand":"Excel Industries","offers":[{"title":"TMIXT","offer_id":51553798259016,"sku":"TMIXT","price":195.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/files\/TMIXT.jpg?v=1759571266"},{"product_id":"thermomix-tmixt2-thermostatic-tap","title":"Thermomix TMIXT2 Thermostatic Tap","description":"\u003cp\u003e\u003cb\u003eDESCRIPTION:\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Taps blend hot and cold water and deliver it at a safe and comfortable pre-calibrated and non user adjustable temperature of 41 Deg. Celsius. They employ a temperature sensitive element which expands and contracts depending on the temperature of the water entering the mixer tap. This expansion and contraction alters the size of the apertures through which the hot and cold water enters the tap; thereby balancing and controlling the outlet temperature of the water and in doing so reducing the risk of scalding accidents.\u003c\/p\u003e\n\u003cp\u003eThermostatic Mixing Taps should ideally be used in all cases where there is a risk of scalding to the user; notably the very young, the very old and those requiring special needs.\u003c\/p\u003e\n\u003cp\u003eThey are therefore ideally suited for School, Hospital and Nursing Home and Health Care Premises application, where, in order to prevent the incidence of Legionella, the stored hot water will be at 60 Degrees Celsius or above.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This tap delivers both premixed hot water and cold water!\u003c\/strong\u003e\u003c\/p\u003e","brand":"Excel Industries","offers":[{"title":"TMIXT2","offer_id":51553809203528,"sku":"TMIXT2","price":294.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/files\/TMIXT2_bf193f32-386b-412f-84e9-ec48940f60dc.jpg?v=1759571334"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0890\/1138\/8744\/collections\/Thermostatic_Mixing_Valves.jpg?v=1746023447","url":"https:\/\/4dkw4i-px.myshopify.com\/collections\/thermostatic-mixing-valves.oembed","provider":"Excel Industries","version":"1.0","type":"link"}